UAV Magnetic Survey reveals large fault structure with multiple associated magnetic
anomalies coinciding with exceptional uranium soil results up to 74,997ppm (7.5%) U3O8
Highlights
Portland Creek UAV magnetics highlight a significant collisional tectonic zone
(primary structure) with a network of interpreted NE-SW trending splay faults
(secondary structures) that may be controlling the ~235m x 100m high grade soil
anomaly with a peak assay result of 74,997 ppm U3O8
Numerous UAV magnetic anomalies identified within the existing historical
radiometric footprint and proximal to the high-grade soil anomaly at Talus may be
associated with undercover primary uranium mineralisation
Second phase infill surface geochemical survey being designed with a tightening
to 50m spaced east-west lines with 10m sample spacing to refine existing broad
anomalism and potentially identify new anomalies
Field crews are mobilising back to site mid-August to complete extensive
geochemical surveying with all samples planned to be submitted via rush order
analysis to expedite diamond drill plans
Infini Resources Ltd (ASX: I88, “Infini” or the “Company”) is pleased to announce its high-resolution
UAV magnetic survey results from the Talus Prospect at its 100% owned Portland Creek Uranium Project.
The Project is located in the uranium-friendly jurisdiction of Newfoundland, Canada (Figure 1 and refer to
ASX announcement 1 July 2024).
Infini’s Managing Director, Charles Armstrong said: “The results of the UAV magnetic survey
are highly encouraging as we have been able to identify a prolific fault system and numerous magnetic
anomalies within the highly prospective 3.2km long radiometric corridor. The Talus prospect now shows
evidence of in-situ mineralisation existing within the primary fault zone as evidenced by the historical
2180ppm U3O8 outcropping grab sample. This primary fault is strongly demagnetised and represents an
excellent target in its own right. The really exciting observation though is seeing secondary faults
underlying the high-grade soil anomaly at Talus, and a network of North-South trending ovoid proximal
magnetic anomalies which may signify undercover uranium mineralisation pods at depth given their
coincidence with both anomalous soils and biogeochemistry. Also of note from the imagery is the large
and wide demagnetised zone underlying the talus colluvium and radiometric anomaly which is a large
target that will also require diamond drill testing.
We are thrilled to be getting back on the ground next month to complete our second, much larger
geochemical sampling program which will assist us to refine existing anomalies and potentially identify
new ones to be fed into planning for a large diamond drill program.”
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
1
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Figure 1 Inset map view of the high grade ~235m x 100m uranium soil anomaly at the Talus Prospect
coincidental with both interpreted structures and radon gas anomalism. NB: The presence of numerous posttectonic magnetic anomalies sitting alongside a large de-magnetized zone.
UAV Magnetic Survey
The high resolution 25m flight line spaced UAV magnetic survey was designed to image the bedrock
structure underlying the large 3.2km radiometric corridor outlined by historical exploration (Figure 1). The
results indicate this was a success with multiple large-scale structures and magnetic anomalies
identified that exhibit strong correlations with existing uranium mineralisation (soil, rock and grab
samples).
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
2
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
The Company is now trying to determine where the primary uranium mineralisation is located:
•
the east within the demagnetised zone and/or a primary fault system?
•
the west if mineralisation is occurring on a sediment-granite contact? or
•
at depth from carbonate sedimentary rocks? given the newfoundland regional government
interpretation is that the regional granites are thrust over the top of sedimentary rocks
The lack of UAV magnetic imagery extending to the west has highlighted the opportunity for the Company
to include an extensional UAV magnetic survey to determine where the sediment-post tectonic granite
contact exists. This contact will be searched for in the field as a part of the phase two surface geochemical
sampling program to enhance the Company’s existing regional geological knowledge.
Figure 2 The UAV drone survey in progress at the Portland Creek Uranium Project.
While there is a distinct drill target corridor forming through the high-grade soil anomaly and demagnetised
corridor directly adjacent to it, it is also important to point out the prominent radiometric anomaly
coincident with a “triple point junction” ~1 km to the south where two interpreted primary faults have been
displaced by a later stage secondary fault (Figure 2).
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
3
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Figure 3 The Talus Uranium Prospect depicting the location of the high-grade soil samples and the large
fault system identified by recently flown 25m flight line spaced UAV magnetics. Note: proof of concept
already exists that the large demagnetized primary fault zone is mineralized with the high-grade grab sample.
Talus Prospect Work Underway
Current work being undertaken in follow up of these excellent first phase geochemical and geophysical
results include: geochemical pathfinder studies, glacial geomorphological studies and the planning of
urgent fieldwork to follow up existing anomalous surface geochemistry and UAV magnetic structures that
have not been sampled. These activities continue to advance the Company towards the execution of a
maiden diamond drill program later in the year that will test a series of conceptual models. A large number
of robust drill targets will be tested with the aim of discovering a new uranium deposit.
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
4
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Figure 4 The Talus Uranium Prospect depicting the location of the highly anomalous biogeochemical
samples and the large fault system identified by recently flown 25m flight line spaced UAV magnetics. Note:
correlation between location of anomalous biogeochemistry and underlying magnetic anomalism.
Bella Bore East Update
The Company has now successfully completed the acquisition of the Bella Bore East uranium project,
following the successful completion of all due diligence requirements (see ASX announcement 3 June
2024). Historical drill hole data will be amalgamated with the aim to complete a conversion from the
historical JORC 2004 inferred resource to JORC 2012 compliant resource status.
About Portland Creek Uranium Project
The Portland Creek Project covers an area of 149 km2 and is situated in the Precambrian Long-Range
Complex of the Humber Tectonic – Stratigraphic zone. These members include metaquartzite and a suite
of paragneisses, intruded by leucocratic pink granite, which have likely been thrust westwards over
Palaeozoic carbonate-dominant sediments. The Claims are situated over a large regional uranium
anomaly that was identified in the 1970’s by a Newfoundland government stream sediment sampling
program. There is one uranium showing on the property as listed in the Newfoundland Mineral Deposit
Index inventory with 2,180 ppm U3O8 (refer Prospectus dated 30 November 2023).
[END]
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
5
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Release authorised by the Board of Infini Resources Ltd.
Contacts
Charles Armstrong
Managing Director and CEO
P: +61 (08) 9465 1051
About Infini Resources Ltd (ASX: I88)
Infini Resources Ltd is an Australian energy metals company focused on mineral exploration in Canada
and Western Australia for uranium and lithium. The company has a diversified and highly prospective
portfolio of assets that includes greenfields and more advanced brownfields projects. The company’s
mission is to increase shareholder wealth through exploration growth and mine development.
JOR 2012 Mineral Resource Deposit
JORC 2012 Classification
Tonnes and Grade
Des Herbiers (U)
Inferred Combined Resource
162 Mt @ 123ppm U3O8
(43.95mlb)
Competent Person’s Statement
The information contained in this announcement that relates to exploration results is based on, and fairly represents, information
and supporting documentation prepared by Mr Charles Armstrong, who is a member of the Australasian Institute of Mining and
Metallurgy (AusIMM) and the Society of Economic Geologists (SEG). Mr Armstrong is Managing Director and Chief Executive
Officer (CEO) of Infini Resources Ltd receiving renumeration and holding securities in the Company. Mr Armstrong has sufficient
experience that is relevant to the style of mineralisation and type of deposit under consideration, and to the activity being undertaken
to qualify as a Competent Person, as defined in the JORC 2012 edition of the “Australasian Code for Reporting of Mineral Resources
and Ore Reserves”. Mr Armstrong consents to the inclusion in this report of the matters based on this information in the form and
context in which they appear.
Compliance Statement
This report contains information on the Company’s Projects extracted from the Company’s Prospectus dated 30 November 2023
and released to the ASX market announcements platform on 10 January 2024, and announcements dated 15 January 2024, 29
January 2024, 19 February 2024, 29 February 2024 3 May 2024, 28 May 2024, 3 June 2024, 13 June 2024, 1 July 2024 and 10
July 2024 reported in accordance with the 2012 edition of the “Australian Code for Reporting of Exploration Results, Mineral
Resources and Ore Reserves” (JORC Code). The original market announcements are available to view on
www.infiniresources.com.au and www.asx.com.au. The Company is not aware of any new information or data that materially affects
the information included in the original market announcement.
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
6
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
This report contains information regarding the Des Herbiers Mineral Resources Estimate extracted from the Company’s Prospectus
dated 30 November 2023 and released to the ASX market announcements platform on 10 January 2024, reported in accordance
with the 2012 edition of the “Australian Code for Reporting of Exploration Results, Mineral Resources and Ore Reserves” (JORC
Code). The Company confirms that it is not aware of any new information or data that materially affects the information included in
any original announcement and that all material assumptions and technical parameters underpinning the estimates in the original
market announcement continue to apply and have not materially changed. The original market announcements are available to
view on www.infiniresources.com.au and www.asx.com.au.
Forward Looking Statements
This announcement may contain certain forward-looking statements and projections. Such forward looking statements/projections
are estimates for discussion purposes only and should not be relied upon. Forward looking statements/projections are inherently
uncertain and may therefore differ materially from results ultimately achieved. Infini Resources Limited does not make any
representations and provides no warranties concerning the accuracy of the projections and disclaims any obligation to update or
revise any forward-looking statements/projects based on new information, future events or otherwise except to the extent required
by applicable laws. While the information contained in this report has been prepared in good faith, neither Infini Resources Limited
or any of its directors, officers, agents, employees or advisors give any representation or warranty, express or implied, as to the
fairness, accuracy, completeness or correctness of the information, opinions and conclusions contained in this announcement.
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
7
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
JORC Code, 2012 Edition – Table 1
Section 1 Sampling Techniques and Data
(Criteria in this section apply to all succeeding sections.)
Criteria
Sampling
techniques
JORC Code explanation
•
•
•
•
Infini Resources Limited
Commentary
Nature and quality of sampling (eg cut channels, random
chips, or specific specialised industry standard
measurement tools appropriate to the minerals under
investigation, such as down hole gamma sondes, or
handheld XRF instruments, etc). These examples should
not be taken as limiting the broad meaning of sampling.
Include reference to measures taken to ensure sample
representivity and the appropriate calibration of any
measurement tools or systems used.
Aspects of the determination of mineralisation that are
Material to the Public Report.
In cases where ‘industry standard’ work has been done this
would be relatively simple (eg ‘reverse circulation drilling
was used to obtain 1 m samples from which 3 kg was
pulverised to produce a 30 g charge for fire assay’). In other
cases more explanation may be required, such as where
there is coarse gold that has inherent sampling problems.
Unusual commodities or mineralisation types (eg
submarine nodules) may warrant disclosure of detailed
information.
ABN 77 656 098 583
•
•
Soil samples were collected by a professional team provided
by an experienced exploration contractor in Canada.
Individual sample locations were located with a handheld
Garmin GPS unit. At each location, a 300-500 g samples
were collected using a Dutch auger. Sampling equipment
was brushed or wiped clean using dirt from the sample site
before each sample was collected to eliminate any residue
from previous samples. The sampling targeted A-horizon
soil, directly below the organic/inorganic interface.
Information about soil sample characteristics and the
collection site were noted, including depth, drainage, slope,
colour, material, water content, vegetation, and topography.
Total count of radiation was tested and recorded for each
sample using an RS-125 Super Spec Handheld Gamma Ray
Spectrometer.
Soil samples were collected on a predetermined grid, spaced
50 m apart along parallel lines with a 100 m spacing. Outside
of this zone soil samples were spaced 100 m apart along
parallel lines with a 200 m spacing.
www.infiniresources.com.au
InfiniResources
8
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Criteria
JORC Code explanation
Commentary
•
•
•
•
Infini Resources Limited
ABN 77 656 098 583
Hand auger soil samples were collected in a similar manner
to soil samples. These targeted a specific local loam layer,
0 cm – 85 cm below the organic/inorganic interface.
Members of the team were trained to identify this layer and
check for its presence at a sample site. Samples were
collected at 12.5 m – 25 m spacing where the loam layer was
identified. Sample radiation levels were measured and
recorded with an RS-125 Super Spec Handheld Gamma Ray
Spectrometer.
Soil samples and hand auger soil samples were submitted
to ALS Geochemical Laboratories’ prep lab in Moncton, NB,
Canada for analysis using the ME-MS41L and MS41L-PbIS
protocols. Any soil samples that exceeded the limit of
detection (LOD) were follow up assayed with the U-XRF15b
ore grade protocol which has a 51% U LOD.
Spectrometer traverse readings were taken using a
calibrated and GPS enabled RS-125 Super-SPEC Handheld
Gamma Ray Spectrometer. The survey mode of operation
was used to collect traverse data.
Biogeochemical samples were collected by a professional
team provided by an experienced exploration contractor in
Canada, on the same grid as the soil samples. Sample sites
were located with a handheld Garmin GPS unit. At each
location, a sample of 250g was collected from 2 or more
trees using pruning shears. Samples targeted 7 years of
growth, including new growth and consisted of branches with
needles included taken at 1.3 m off the ground. Data
recorded for each sample included the number of trees
sampled, the area of ground containing the trees sampled,
the type of tree, ground conditions, evidence of stressed
growth or soil contamination.
www.infiniresources.com.au
InfiniResources
9
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Criteria
JORC Code explanation
Commentary
•
•
•
•
•
Infini Resources Limited
ABN 77 656 098 583
Biogeochemical samples were submitted to ALS
Laboratories’ Moncton for analysis using the ME-VEG41a
protocol.
Rock grab samples were collected by the field team where
geology of interest was encountered; samples of 200-1000
g were collected. Locations, photos, and descriptions of the
samples were recorded.
Rock samples were submitted to ALS Laboratories Moncton
for analysis using the ME-MS81d protocol.
The UAV magnetic survey over the Portland Creek project
was flown along 25m spaced lines oriented N0900 (UTM) for
a total of 118.4 line kilometers. The drone used for this
survey is the Skylle 1550 model from MMC. This drone is a
multi-rotor (six motors) with a weight of 11.5 kg (including
batteries). The drone navigates using two ZED-F9P dual
frequency GPS receivers that communicate together via a
900 Mhz telemetry link. One GPS (base) is stationary at the
staging site and the other is located on the aircraft (rover).
The base GPS station sends position corrections over the
radio link to the rover in order to compensate for external
errors, mostly caused by atmospheric conditions that
normally dilute the precision of a single receiver to multiple
metres. This method, called RTK or Real-Time Kinematics,
allows the system to maintain centimetre-level accuracy in
the horizontal and vertical axis, the latter of which is
particularly important regarding magnetic surveys. After the
survey, data is reprocessed using Post-Processed
Kinematics (PPK) to validate the accuracy of the real-time
solution.
The magnetometer used for the survey was a Scintrex CS-V
cesium vapour device. This magnetometer is powered by a
independent battery. The CS-VL has a measurement rang
between 15,000 nT and 105,000 nT with a sensitivity o
www.infiniresources.com.au
InfiniResources
10
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Criteria
JORC Code explanation
Commentary
0.0006nT/√Hz. The magnetometer is installed in a custom-bui
plastic bird shell allowing a controlled orientation of th
magnetometer during flights. The bird shell is towed at five (5
meters below the drone.
Drilling
techniques
•
Drill type (eg core, reverse circulation, open-hole hammer,
rotary air blast, auger, Bangka, sonic, etc) and details (eg
core diameter, triple or standard tube, depth of diamond
tails, face-sampling bit or other type, whether core is
oriented and if so, by what method, etc).
•
Not applicable due to no drilling undertaken.
Drill sample
recovery
•
Method of recording and assessing core and chip sample
recoveries and results assessed.
Measures taken to maximise sample recovery and ensure
representative nature of the samples.
Whether a relationship exists between sample recovery and
grade and whether sample bias may have occurred due to
preferential loss/gain of fine/coarse material.
•
Not applicable due to no drilling undertaken.
Whether core and chip samples have been geologically and
geotechnically logged to a level of detail to support
appropriate Mineral Resource estimation, mining studies
and metallurgical studies.
Whether logging is qualitative or quantitative in nature.
Core (or costean, channel, etc) photography.
The total length and percentage of the relevant
intersections logged.
•
Not applicable due to no drilling undertaken.
If core, whether cut or sawn and whether quarter, half or all
core taken.
If non-core, whether riffled, tube sampled, rotary split, etc
and whether sampled wet or dry.
For all sample types, the nature, quality and
appropriateness of the sample preparation technique.
•
Not applicable due to no drilling undertaken.
•
•
Logging
•
•
•
Sub-sampling
techniques
and sample
preparation
•
•
•
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
11
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Criteria
JORC Code explanation
•
•
•
Infini Resources Limited
Commentary
Quality control procedures adopted for all sub-sampling
stages to maximise representivity of samples.
Measures taken to ensure that the sampling is
representative of the in situ material collected, including for
instance results for field duplicate/second-half sampling.
Whether sample sizes are appropriate to the grain size of
the material being sampled.
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
12
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Quality of
assay data
and laboratory
tests
•
•
•
The nature, quality and appropriateness of the assaying
and laboratory procedures used and whether the technique
is considered partial or total.
For geophysical tools, spectrometers, handheld XRF
instruments, etc, the parameters used in determining the
analysis including instrument make and model, reading
times, calibrations factors applied and their derivation, etc.
Nature of quality control procedures adopted (eg standards,
blanks, duplicates, external laboratory checks) and whether
acceptable levels of accuracy (ie lack of bias) and precision
have been established.
•
•
•
•
•
•
Infini Resources Limited
ABN 77 656 098 583
Soil Samples
Assay techniques are ME-MS41L and MS41L-PbIS which
are a ‘Total Technique’ for uranium exploration. Super trace
aqua regia and four acid-digestions are ideal for soil and
sediment samples where background values improve
anomaly identification. The Pb Isotope add-on is useful for
pathfinder purposes when attempting to vector in on
undercover uranium mineralisation.
Biogeochemical Samples
Assay technique is ME-VEG41a which is an appropriate
‘Total Technique’ for undercover uranium exploration. After
ashing this technique uses an aqua regia digest to produce
50+ elements that are reported with the industry’s lowest
detection levels.
Rock Samples
Assay technique is ME-MS81d which is an appropriate ‘Total
Technique’ for uranium exploration. The lithium borate fusion
prior to acid dissolution and ICP-MS analysis provides the
most quantitative analytical approach for a broad suite of
trace elements in rock samples.
Standard laboratory QAQC is undertaken and monitored by
the laboratory and by the company upon assay result
receival.
Soil sampling QAQC was performed in the field by flushing
the sampling equipment clean with soil from the sample site
before being collected to eliminate any residue from
previous samples. Duplicate samples were taken to
maintain 5-10% QAQC. This was performed by taking a
second sample from the same site but from a different hole.
Biogeochemical sampling QAQC was performed by
maintaining duplicate samples at 5-10% where a second
set of spruce branches and needles were taken from the
same sample site at a different side of the tree.
www.infiniresources.com.au
InfiniResources
13
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Criteria
Verification of
sampling and
assaying
JORC Code explanation
•
•
•
•
Location of
data points
•
•
•
Data spacing
and
distribution
•
•
•
Commentary
The verification of significant intersections by either
independent or alternative company personnel.
The use of twinned holes.
Documentation of primary data, data entry procedures, data
verification, data storage (physical and electronic)
protocols.
Discuss any adjustment to assay data.
•
Where appropriate the company has converted original ppm
U assay data to ppm U3O8 using the conversion factor of
1.1792.
Accuracy and quality of surveys used to locate drill holes
(collar and down-hole surveys), trenches, mine workings
and other locations used in Mineral Resource estimation.
Specification of the grid system used.
Quality and adequacy of topographic control.
•
•
All sample location data is in NAD83 UTM Zone 21N.
Soil samples, biogeochemical samples and spectrometer
traverse sites were surveyed by a handheld GARMIN GPS
with an accuracy of +/- 3m.
Data spacing for reporting of Exploration Results.
Whether the data spacing and distribution is sufficient to
establish the degree of geological and grade continuity
appropriate for the Mineral Resource and Ore Reserve
estimation procedure(s) and classifications applied.
Whether sample compositing has been applied.
•
Soil and biogeochemical samples were collected on a
predetermined grid, spaced 50 m apart along parallel lines
with a 100 m spacing. Outside of this zone soil samples
were mostly spaced 100 m apart along parallel lines with a
200 m spacing. This is considered appropriate at this stage
of exploration where radiometric anomalism already exists
warranting more targeted and tighter spacing of sample
sites.
Not applicable as no Mineral Resource and Ore Reserves
are reported.
No sample compositing has been applied.
•
•
Orientation of
data in relation
to geological
structure
Infini Resources Limited
•
•
Whether the orientation of sampling achieves unbiased
sampling of possible structures and the extent to which this
is known, considering the deposit type.
If the relationship between the drilling orientation and the
orientation of key mineralised structures is considered to
have introduced a sampling bias, this should be assessed
and reported if material.
ABN 77 656 098 583
•
The soil, biogeochemical sampling and spectrometer
traverse data was undertaken across and through the strike
of known radiometric anomalism within the project areas.
www.infiniresources.com.au
InfiniResources
14
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Criteria
JORC Code explanation
Commentary
•
The UAV magnetic survey lines were flown along 25m
spaced lines oriented N0900 (UTM) for a total of 118.4 line
kilometers. These flight lines are oriented perpendicular to
the historical radiometric anomalism and interpreted major
ductile fault system which is considered appropriate for this
early level of exploration.
Sample
security
•
The measures taken to ensure sample security.
•
Field samples were collated by field staff who freighted the
samples to ALS Moncton, NB, Canada for rush order
analysis.
Audits or
reviews
•
The results of any audits or reviews of sampling techniques
and data.
•
None carried out to date.
Infini Resources Limited
ABN 77 656 098 583
www.infiniresources.com.au
InfiniResources
15
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Section 2 Reporting of Exploration Results
(Criteria listed in the preceding section also apply to this section.)
Criteria
Mineral
tenement and
land tenure
status
JORC Code explanation
•
•
Exploration
done by other
parties
•
Commentary
Type, reference name/number, location and ownership
including agreements or material issues with third parties
such as joint ventures, partnerships, overriding royalties,
native title interests, historical sites, wilderness or national
park and environmental settings.
The security of the tenure held at the time of reporting
along with any known impediments to obtaining a licence to
operate in the area.
•
•
Acknowledgment and appraisal of exploration by other
parties.
•
•
•
•
Infini Resources Limited
ABN 77 656 098 583
The Talus prospect is located on 036683M and 036684M.
The Portland Creek uranium project comprises seven
mineral claims (036683M, 036684M, 036685M, 037492M,
037490M, 037496M and 037495M). The company staked
the project in 2023/24 (100% ownership) and is not aware of
any royalties existing on the claims or impediments to
obtaining a license to operate in the area.
The claims are currently live and in good standing.
Exploration between 1976 and 1980 was carried out by the
Conwest Canadian Uranium Exploration JV. Work included
radon gas sampling, a scintillometer survey, and VLF-EM
and ground magnetics. Follow-up drilling using a portable
“Pionjar” drill capable of drilling to 8 m depth which identified
a small, high grade uranium anomaly (so-called “loam
deposit”). Only very sparse details survive on this drilling
program with no assay results or drill hole locational data
able to be verified under the JORC code. Five diamond holes
were drilled. Partial results have been found for only one of
these, which reported unmineralized granite.
Subsequent exploration in 2007 included Ucore flying an
airborne IMPULSE survey and collecting 8 rock samples and
in 2009, Novtem Airborne Geophysics flew a magnetic
survey. The property was abandoned shortly after.
Current modern exploration is now being undertaken
thoroughly by Infini Resources and includes soil,
biogeochemical, spectrometer, LiDAR and UAV magnetic
surveys in addition to geological mapping with rock
sampling.
www.infiniresources.com.au
InfiniResources
16
Major Fault System & Magnetic Anomalies Identified at Talus Uranium Prospect
Criteria
Geology
JORC Code explanation
•
Commentary
Deposit type, geological setting and style of mineralisation.
•
Share your feedback
Discover